Addressable Modules MAD-442
Addressable monitor module of 2 conventional zones, allows the connection of up to 20 conventional detectors and / or 32 conventional manual call points per zone. Can identify between detector and manual call point alarm as well as between the fault by cutting or by short circuit of the zone. It takes two loop addresses. Requires 24 Vdc auxiliary power supply. LED status indicator. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-ONE. Consumption less than 300μA at rest. Allows installation without polarity. Red color. Dimensions: 100 x 82 x 23 mm. CPR certificate EN 54-18.
-
Addressable Modules MAD-481
Addressable module with 1 voltage-free relay output of 240 Vac and 5A that provides a non-resettable C, NO, NC contact. It occupies an address in the loop. Direct power from the loop. Includes status indicator LED. Connection by means of removable strips of up to 2.5mm2 section. Possibility of being installed on a DIN rail or flat wall mounting in a BOX-ONE box. Consumption less than 300μA at rest. Red color. Dimensions 100 x 82 x 23mm.
-
Addressable Modules MAD-490
Addressable short-circuit protection isolating module, with status LED, which isolates the loop section between two isolators in the event of a short-circuit in the loop. Takes no address in the loop. Direct feed from the loop. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-ONE. Consumption less than 300μA at rest. Red color. Dimensions: 100 x 82 x 23 mm. CPR certificate EN 54-17.
-
Addressable Modules MAD-401-I
Addressable monitor module with built-in isolator of 1 supervised technical input for status indication of equipment providing NC or NO contact. It takes one loop address. Direct feed from the loop. LED status indicator. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-ONE. Consumption less than 300μA at rest. Red color. Dimensions: 100 x 82 x 23 mm. CPR certificate EN 54-18 and EN 54-17.
-
Addressable Modules MAD-402-I
Addressable monitor module with built-in isolator of 2 supervised technical inputs for status indication of equipment providing NC or NO contact. It takes two loop addresses. Direct feed from the loop. LED status indicator. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-ONE. Consumption less than 300μA at rest. Red color. Dimensions: 100 x 82 x 23 mm. CPR certificate EN 54-18 and EN 54-17.
-
Addressable Modules MAD-411-I
Addressable control module with built-in isolator of 1 voltage-free relay output providing non-resettable C, NO, NC contact. It takes one loop address. Direct feed from the loop. LED status indicator. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-ONE. Consumption less than 300μA at rest. Red color. Dimensions: 100 x 82 x 23 mm. CPR certificate EN 54-18 and EN 54-17.
-
Addressable Modules MAD-412-I
Addressable control module with built-in isolator of 2 relay outputs free of voltage that provides two contacts C, NO, NC non-resettable. It takes two loop addresses. Direct feed from the loop. LED status indicator. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-400. Consumption less than 300μA at rest. Red color. Dimensions: 100 x 82 x 23 mm. CPR certificate EN 54-18 and EN 54-17.
-
Addressable Modules MAD-421-I
Addressable monitor and control module with built-in isolator of 1 supervised technical input for the status signaling of equipment that provides NC or NO contact and 1 voltage-free relay output providing non-resettable C, NO, NC contact. It takes two loop addresses. Direct feed from the loop. LED status indicators. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-ONE. Consumption less than 300μA at rest. Red color. Dimensions: 100 x 82 x 23 mm. CPR certificate EN 54-18 and EN 54-17.
-
Addressable Modules MAD-422-I
Addressable monitor module and control with built-in isolator of 2 supervised technical inputs for the status signaling of equipment that provide NC or NO contact and 2 voltage-free relay outputs providing two non-resettable C, NO, NC contacts. It occupies four directions in the loop. Direct feed from the loop. LED status indicators. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-ONE. Consumption less than 300μA at rest. Red color. Dimensions: 100 x 82 x 23 mm. CPR certificate EN 54-18 and EN 54-17.
-
Addressable Modules MAD-431-I
Addressable control module with built-in isolator of 1 monitored 24V output, for the activation of optical-acoustic signaling devices or maneuvers that require power, discriminating the breakdown or short-circuit fault in said line. It takes one loop address. Requires 24 Vdc auxiliary power supply. LED status indicator. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-ONE. Consumption less than 300μA at rest. Red color. Dimensions: 100 x 82 x 23 mm. CPR certificate EN 54-18 and EN 54-17.
-
Addressable Modules MAD-432-I
Addressable control module with built-in isolator of 2 supervised 24V outputs, for the activation of optical-acoustic signaling devices or maneuvers requiring power, discriminating the breakdown or short-circuit fault in said line. It takes two loop addresses. Requires 24 Vdc auxiliary power supply. LED status indicator. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-ONE. Consumption less than 300μA at rest. Red color. Dimensions: 100 x 82 x 23 mm. CPR certificate EN 54-18 and EN 54-17.
-
Addressable Modules MAD-441-I
Addressable monitor module with built-in isolator of 1 conventional zone, allows the connection of up to 20 conventional detectors and / or 32 conventional manual call points. Can identify between detector and manual call point alarm as well as between the fault by cutting or by short circuit of the zone. It takes one loop address. Requires 24 Vdc auxiliary power supply. LED status indicator. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-ONE. Consumption less than 300μA at rest. Red color. Dimensions: 100 x 82 x 23 mm. CPR certificate EN 54-18 and EN 54-17.
-
Addressable Modules MAD-442-I
Addressable monitor module with built-in isolator of 2 conventional zones, allows the connection of up to 20 conventional detectors and / or 32 conventional manual call points per zone. Can identify between detector and manual call point alarm as well as between the fault by cutting or by short circuit of the zone. It takes two loop addresses. Requires 24 Vdc auxiliary power supply. LED status indicators. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-ONE. Consumption less than 300μA at rest. Red color. Dimensions: 100 x 82 x 23 mm. CPR certificate EN 54-18 and EN 54-17.
-
Addressable Modules MAD-405-I
Addressable monitor module with built-in isolator of 5 supervised technical inputs for status indication of equipment providing NC or NO contact. It takes five loop addresses. Direct feed from the loop. LED status indicator. Connection through removable strips up to 2.5mm2 section. Includes mounting box. Dimensions: 172 x 170 x 48 mm. CPR certificate EN 54-18 and EN 54-17.
-
Addressable Modules MAD-409-I
Addressable monitor module with built-in isolator of 10 supervised technical inputs for status indication of equipment providing NC or NO contact. It takes ten loop addresses. Direct feed from the loop. LED status indicator. Connection through removable strips up to 2.5mm2 section. Includes mounting box. Dimensions: 172 x 170 x 48 mm. CPR certificate EN 54-18 and EN 54-17.
-
Addressable Modules MAD-415-I
Addressable control module with built-in isolator of 5 relay outputs free of voltage that provides two contacts C, NO, NC non-resettable. It takes five loop addresses. Requires external 24 Vdc power. LED status indicator. Connection through removable strips up to 2.5mm2 section.Includes mounting box. Dimensions: 172 x 170 x 48 mm. CPR certificate EN 54-18 and EN 54-17.
-
Addressable Modules MAD-419-I
Addressable control module with built-in isolator of 10 relay outputs free of voltage that provides two contacts C, NO, NC non-resettable. It takes ten loop addresses. Requires external 24 Vdc power. LED status indicator. Connection through removable strips up to 2.5mm2 section. Includes mounting box. Dimensions: 172 x 170 x 48 mm. CPR certificate EN 54-18 and EN 54-17.
-
Addressable Modules MAD-425-I
Addressable monitor module and control with built-in isolator of 5 supervised technical inputs for the status signaling of equipment that provide NC or NO contact and 5 voltage-free relay outputs providing two non-resettable C, NO, NC contacts. It occupies 10 adressess in the loop. Requires external 24 Vdc power. LED status indicators. Connection through removable strips up to 2.5mm2 section. Includes mounting box. Dimensions: 172 x 170 x 48 mm. CPR certificate EN 54-18 and EN 54-17.
-
Addressable Modules MAD-429-I
Addressable monitor module and control with built-in isolator of 10 supervised technical inputs for the status signaling of equipment that provide NC or NO contact and 10 voltage-free relay outputs providing two non-resettable C, NO, NC contacts. It occupies 20 adressess in the loop. Requires external 24 Vdc power. LED status indicators. Connection through removable strips up to 2.5mm2 section. Includes mounting box. Dimensions: 172 x 170 x 48 mm. CPR certificate EN 54-18 and EN 54-17.
-
Addressable Modules BOX-ONE
Transparent box for installation of one addressable module of the MAD-400 series. Dimensions: 172 x 170 x 48 mm.
-
Addressable Modules BOX-SIX
Transparent box for installation of addressable modules of the MAD-400 series. Maximum capacity of 6 modules. Dimensions: 172 x 170 x 110 mm.
-
Software SGD-151-1-CCD
Graphic software license for one conventional control panel. Control, supervision and management of the fire detection installation in graphic environment (PC).
-
Software SGD-151-E-CCD
Additional graphic software license for one conventional control panel. Control, supervision and management of the fire detection installation in graphic environment (PC).
-
Software SGD-151-1-2L
Graphic software license for one addressable control panel series with up to 2 loops. Control, supervision and management of the fire detection installation in graphic environment (PC). SGD graphical monitoring software supports till 5 slave (PC) substations.
-
Software SGD-151-E-2L
Additional graphic software license for 2 added loops on one addressable control panel series. Control, supervision and management of the fire detection installation in graphic environment (PC). SGD graphical monitoring software supports till 5 slave (PC) substations.
-
Software SGD-151-1-32L
Graphic software license for one addressable control panel series with up to 32 loops. Control, supervision and management of the fire detection installation in graphic environment (PC). SGD graphical monitoring software supports till 5 slave (PC) substations.
-
Software SGD-151-E-5E
Monitoring software license extension for 5 additional slave stations.
-
ECO Control Panels CCD-020
Detnov 2-zone ECO-series conventional fire alarm control panel.
-
ECO Control Panels CCD-040
Detnov 4-zone ECO-series conventional fire alarm control panel.
-
CCD-100 Control Panels CCD-102
Detnov 2-zone CCD-100-series conventional fire alarm control panel.
-
CCD-100 Control Panels CCD-104
Detnov 4-zone CCD-100-series conventional fire alarm control panel.
-
CCD-100 Control Panels CCD-108
Detnov 8-zone CCD-100-series conventional fire alarm control panel.
-
CCD-100 Control Panels CCD-112
Detnov 12-zone CCD-100-series conventional fire alarm control panel.
-
CCD-100 Accessories TRD-100
Accessory or communications/service component for Detnov CCD-100 conventional control systems.
-
CCD-100 Accessories TSD-100
Accessory or communications/service component for Detnov CCD-100 conventional control systems.
-
CCD-100 Accessories TMD-100
Accessory or communications/service component for Detnov CCD-100 conventional control systems.
-
CCD-100 Accessories TPLD-100
Accessory or communications/service component for Detnov CCD-100 conventional control systems.
-
CCD-100 Accessories CCC-100
Accessory or communications/service component for Detnov CCD-100 conventional control systems.
-
CCD-100 Accessories SWD-100
Accessory or communications/service component for Detnov CCD-100 conventional control systems.
-
Conventional Detectors DOD-320
Detnov conventional optical smoke detector for the 200/300-series platform.
-
Conventional Detectors DOTD-330
Detnov conventional combined smoke and heat detector for the 200/300-series platform.
-
Conventional Detectors DTD-310
Detnov conventional heat detector for the 200/300-series platform.
-
Conventional Detectors DOD-220
Detnov conventional optical smoke detector for the 200/300-series platform.
-
Conventional Detectors DOTD-230
Detnov conventional combined smoke and heat detector for the 200/300-series platform.
-
Conventional Detectors DTD-210
Detnov conventional heat detector for the 200/300-series platform.
-
Conventional Detectors DTD-215
Detnov conventional heat detector for the 200/300-series platform.
-
Conventional Detectors DOD-320-B
Detnov conventional optical smoke detector for the 200/300-series platform. Black finish.
-
Conventional Detectors DOTD-330-B
Detnov conventional combined smoke and heat detector for the 200/300-series platform. Black finish.
Not sure which part you need?